Thomas More Square

Accessible Version

Get Adobe Flash player


the scheme

overview

Thomas More Square is a perfectly formed business village Plugged into the world, on the edge of the Square Mile, minutes from London City Airport, it rubs shoulders with the luxury yachts and ocean going cruisers berthed in St Katherine Docks.

We have injected the infrastructure with a fresh lease of life, upgrading and refurbishing reception areas and revitalizing office accommodation. New gardens fill the piazzas and courtyards with greenery. The cafés and bars are welcoming customers and the buildings hum with activity.

Back to top


property management

Property Management has a critical role to play as part of the Land Securities Group, providing the day to day contact with our customers. The Thomas More Square property management team is dedicated to adding real value to our occupiers' businesses through effective and flexible working practices.

The team is from a wide cross section of backgrounds, bringing practical benefits to the successful management of this campus site. By ensuring that the property management team are on site and accessible when our customers need them, we have been able to develop closer working relationships with our occupiers, to understand their needs and meet and exceed their expectations.

Back to top


testimonials

"The Thomas More Square complex is an ideal location in view of its close proximity to restaurants, shops and other eating establishments in the area. It is also very close to Waitrose supermarket which provides excellent facilities as well as an in-house café.

It is a well maintained location very close to St. Katherine Docks which provides various amenities in very pleasant surroundings. The complex is highly maintained and the Building Management are always very helpful and accommodating to our needs. There are good transport links to Liverpool Street Station and the rest of the City of London is within walking distance."

Jean James United Arab Shipping, 6 Thomas More Square

Back to top


walking routes

walking routes

Back to top


local area

connections

Download PDF

connections

Back to top


neighbours

Download PDF

neighbours

Back to top


amenities

Download PDF

amenities

Back to top


2 thomas more square

introduction

The refurbished office space is good quality, flexible accommodation, with raised floors and high-capacity air conditioning. Space can be leased vertically in self-contained buildings with 11,000 to 15,800 square feet areas, or we can join connecting buildings to make 35,000 square feet floor plates. A new reception area has created an attractive entrance, and landscaping fills the plazas with lush greenery.

Back to top


2 thomas more square - masterplan

masterplan

Back to top


2 thomas more square - schedule

2 thomas more square - schedule

Back to top


2 thomas more square - floorplans

Download PDF

2 thomas more square - floorplans

Back to top


2 thomas more square - 2spaceplans

2 thomas more square - spaceplans

Back to top


2 thomas more square - specification

Download PDF

Occupancy Levels
1 person/10 sqm of net lettable.

Structural Grid
Generally a 7.5 x 7.5m square grid.

Floor to Ceiling Heights
Ground/1st 2.95m, 2nd up 2.75m.

Raised Floor Depth (in floor thickness)
Ground 350mm, 1st 275mm and
2nd up 200mm.

Floor Loadings
Office Areas 4 + 1 kN/sq m.

Cycle Spaces
Can accommodate approximately 200 cycles within a secure CCTV covered area.

Mechanical Services
Ceiling Void VAV air conditioning system to provide cooling loads as follows:
Lighting 12W/m2, Office Equipment 30W/m2. Space can be found for additional tenants requirements.

Electrical Services
New lighting installation including lighting control system and emergency lighting. New Fire Detection system.

Standby Power Provision
A 720KVg diesel standby generator is installed at roof level. Subject to agreement this may be utilised by incoming tenants.

Lifts
3 passenger (16 person 1,250kg)
1 goods (13 person 1,000kg)
2 fireman's (8 person 830kg).

Back to top


2 thomas more square - sustainability

Download PDF

Chiller/ Heat Pump Refrigerant
All of the new refrigeration machines being utilised on the site will be selected to operate using zero-depletion, "ozone-friendly" refrigerant gases.

Motor Power Conservation
Many of the pump and fan motors have been supplied with the new inverter speed controller. These inverters regulate the energy drawn by the motor to suit the energy required by the operation of the system. This is particularly beneficial on the office ventilation cooling systems where the load requirements are continually varying.

Lighting Control System
To comply with the current Building Regulations and energy conservation requirements, the new lighting control system will incorporate a number of energy efficient devices.

• Remote monitoring and switching control
The new systems will have the facility for remote monitoring and operational switching. This has the benefit of the system control being possible from remote locations.

• Daylight monitoring and dimming control
Sensors built into the system will monitor the level of ambient lighting levels within the space and automatically vary the output of the luminaries and at the same time maintain a constant light level within the space thus saving energy.

• Presence Detection
Presence detectors included within the installation will monitor the movement of occupants within defined areas of the building. The lights within this area will be set on a timer and will automatically turn off if no further movement is dedicated. This is particularly useful in areas of intermittent use, like toilets, meeting rooms, cleaner's cupboards and some corridors.

Low-Energy Lamps
Where possible, low-energy lamps have been selected for luminaries within the lighting installation. These have the benefit of using less energy than standard filament type lamps and have a longer operating life.

Air Handling Unit Thermal Wheels
Thermal wheels are used within the air handling units to reclaim heat from extracted air from the office space and use it to assist in either the pre-heating or pre-cooling of the supply air to the office space cooling system.

BMS Control
The inclusion of the BMS system allows constant monitoring and control adjustment of the plant operation during its ever changing condition. This optimises the use of energy to suit those varying load conditions.

There are a number of functions of the BMS which are of benefit to the use and conservation of energy. The primary source of this is Plant Optimisation Control.

• Plant Optimisation Control
The purpose of the plant optimiser is, over a period of time, to gather data of the operation of the building plant and compare this with the internal and external conditions.

This will determine the optimum time to initiate plant start-up and ensure comfortable internal conditions at the desired occupancy periods.

It continuously monitors internal and external conditions even when plant is not operating and will decide when plant needs to come on to maintain conditions within the building.

Water Flow Regulators
Each of the taps and basin outlets will be fitted with flow limiting valves. These devices control and regulate the quantity of water that a tap discharges thus saving water usage.

Toilet Core Solenoid Valves
A motorised shut-off valve has been installed to each of the public health services supply pipes feeding each toilet core.

This valve works in unison with a presence detector located within the toilet area. If no movement is sensed within the toilet for a pre-set time period the valve will shut and isolate the water services. Upon sensing movement the valve re-opens and services supply is reinstated. This is of particular benefit if taps are left on or leaks develop in non-visible areas.

Urinal Flush PIR
A PIR has been installed to regulate the flow of water to the urinal flush cisterns. Again on sensing movement within the toilet area the flush cistern will fill and flush.

This is of benefit in periods when toilets are not in use, ie. weekends, bank holidays and evenings.

These are the main "green" energy/resources-saving processes being implemented on the Thomas More Square service designs.

Furthermore the building has achieved a "VERY GOOD" BREEAM (Building Research Establishment Environmental Assessment Method) rating.

Back to top


3 thomas more square

introduction

The office space is good quality, flexible accommodation, with raised floors and high-capacity air conditioning. Space can be leased vertically in self-contained buildings with 4,300 to 20,000 square feet areas, or we can join connecting buildings to make 35,000 square feet floor plates. A refreshed reception area has created an attractive entrance, and landscaping fills the plazas with lush greenery.

Back to top


3 thomas more square - masterplan

masterplan

Back to top


3 thomas more square - schedule

schedule

Back to top


3 thomas more square - floorplans

Download PDF

floorplans

Back to top


3 thomas more square - spaceplans

2 thomas more square - spaceplans

Back to top


3 thomas more square - specification

Download PDF

Occupancy Levels
1 person/10 sq m of net lettable.

Structural Grid
Generally a 7.5 x 7.5m square grid.

Floor to Ceiling Heights
Ground/1st 2.95m, 2nd up 2.75m.

Depth (incl. floor thickness)
Ground 350mm, 1st 275mm and 2nd up 200mm.

Floor Loadings
Office areas 4 + 1 kN/sq m.

Cycle Spaces
Can accommodate approximately 200 cycles within a secure CCTV covered area.

Parking
Approx 164 public car spaces on site and 174 private spaces located at basement level serving the offices.

Mechanical Services
Ceiling void VAV air conditioning system to provide cooling loads as follows:
Lighting 12w/sq m, small power 30w/sq m. Space can be found for additional tenants requirements.

Electrical Services
New lighting installation including lighting control system and emergency lighting. Refurbished fire detection system.

Standby Power Provision
Diesel standby power generator provided for life safety systems.

Lifts
4 passenger 24 person
1,800kg serving floors 1-7,
4 passenger 24 person
1,800kg serving floors 7-13,
2 goods 13 person 1,000kg
serving all floors,
2 fireman's 8 person 830kg
serving all floors.

Back to top


3 thomas more square - sustainability

Download PDF

Mechanical Services
Cooling to the tenants' area is provided in the main by ceiling void VAV air conditioning units.

The base build design loads are as follows:
Lighting 12 w/sq m
Small power 30 w/sq m.

There is some space available for future tenants' plant at both roof and car park levels. This would be subject to landlord's approval.

New refrigeration plant has recently been installed serving 3TMS. Control of the air conditioning system is achieved by a site-wide BMS system.

Electrical Services
Although served by an incoming EDF electrical supply, 3TMS has 3MVA of installed generator power at roof level (2MVA available for tenants - subject to agreement) dedicated to the building.

Electrical infrastructure comprises of 2 rising electrical busbar systems, each serving half of a floor (notional split). Lighting is provided to the floor plates by recessed modular lighting.

Life Safety
Life-safety is achieved by a full detection system with voice activated evacuation system. Smoke clearance is achieved by a fully functional smoke management system.

Lifts
New passenger, goods and fireman's lifts have been installed within the building. In parallel with the new lifts, a "Hall Call" destination system has been installed to ensure fully automated and time-saving lift waiting and travel times.

Back to top


view

2 thomas more square - views

Reception desk
view from top floor

Reception sitting area
reception

Lifts
atrium

Atrium
atrium

View from the top floor
atrium

Back to top


3 thomas more square - views

Exterior view
reception

Reception
entrance

Atrium
atrium

View from top floor
plaza

Back to top


public realm

Entrace Gate - computer generated image
building

Landscaped plaza - computer generated image
reception

Back to top


aerial view

building

Back to top


available space

schedule

Back to top


downloads

2 thomas more square - views
Floorplans PDF (175kb)
Specification PDF (45kb)
Sustainability PDF (45kb)

3 thomas more square - views
Floorplans PDF (175kb)
Specification PDF (45kb)
Sustainability PDF (45kb)

Back to top


contacts

Owners
Land Securities
5 Strand
London WC2N 5AF
United Kingdom

The Cadillac Fairview Corporation Limited
20 Queen Street West
Toronto
Ontario M5H 3R4
Canada

For more information please contact our leasing agents:
BH2:
Neal Scambler
020 7710 7953
neals@bh2.co.uk

Tom Kemp
020 7710 7955
tomk@bh2.co.uk

DTZ:
Tim Plumbe
020 3296 2005
tim.plumbe@dtz.com

Jonathan Huckstep
020 3296 2006
jonathan.huckstep@dtz.com

Matthew Flood
020 3296 2218
matthew.flood@dtz.com

Back to top


Land Securities logo